| Sign In | Join Free | My benadorassociates.com |
|
Brand Name : Rexroth
Model Number : 4WRZ10E3-85-7X/6EG24N9ETK4/D3M 4WRZ10E3-85-7X/6EG24N9ETK4/M 4WRZ10E3-85-7X/6EG24N9EK4/D3M
Certification : ISO
Place of Origin : German
MOQ : 1
Price : 2
Payment Terms : MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability : 100
Delivery Time : 2 weeks
Packaging Details : wooden box
Material : Cast Iron
Power : Hydraulic
Transport Package : Wooden Box
Seal Type : Lip Seal or Mechanical Seal
Charging : micro5p
Color : customised making
Type : Piston Pump
Delivery Date : 5 days
Housing Material : Cast Iron
Mounting Type : Flange
Rotation : 0.2-cp can be transported in reverse
Oil : Mineral oil or synthetic oil
4WRZ10E3-85-7X/6EG24N9ETK4/D3M
4WRZ10E3-85-7X/6EG24N9ETK4/M
4WRZ10E3-85-7X/6EG24N9EK4/D3M Original proportional directional valve, German Rexroth hydraulic valve
| Processing & Customization | yes | type | proportional valve |
| material | cast steel | model | 4WRZ10E3-85-7X/6EG24N9ETK4/D3M 4WRZ10E3-85-7X/6EG24N9ETK4/M 4WRZ10E3-85-7X/6EG24N9EK4/D3M |
| brand | REXROTH | Scope of Application | hydraulic system |
| Product Alias | Proportional directional valve | Applicable Medium | oil products |
| Applicable Temperature | Normal temperature (℃) ℃ | Nominal Pressure | Normal pressure (MPa) MPa |
| Nominal Diameter | 6-way diameter (mm) mm | Installation type | Threaded installation |
| Operating Temperature | room temperature | Type (channel location) | Straight through type |

| 4WRZ10E1-85-70/6EG24N9TK4/M |
| 4WRZ10E1-85-70/6EG24N9ETK4/D3M |
| 4WRZ10E1-85-70/6EG24N9ETK4/M |
| 4WRZ10E1-85-70/6EG24N9EK4/D3M |
| 4WRZ10E1-85-70/6EG24N9EK4/M |
| 4WRZ10E1-85-70/6EG24N9K4/D3M |
| 4WRZ10E1-85-70/6EG24N9K4/M |
| 4WRZ10E1-50-70/6EG24N9TK4/D3M |
| 4WRZ10E1-50-70/6EG24N9TK4/M |
| 4WRZ10E1-50-70/6EG24N9ETK4/D3M |
| 4WRZ10E1-50-70/6EG24N9EK4/D3M |
| 4WRZ10E85-70/6EG24N9K4/M |
| 4WRZ10E1-50-70/6EG24N9EK4/M |
| 4WRZ10E1-50-70/6EG24N9K4/D3M |
| 4WRZ10E1-50-70/6EG24N9K4/M |
| 4WRZ10E1-25-70/6EG24N9EK4/M*** |
| 4WRZ10E1-25-70/6EG24N9K4/D3M |
| 4WRZ10E1-25-70/6EG24N9K4/M |
| 4WRZ10E85-70/6EG24N9TK4/D3M |
| 4WRZ10E85-70/6EG24N9TK4/M |
| 4WRZ10E85-70/6EG24N9ETK4/D3M |
| 4WRZ10E85-70/6EG24N9ETK4/M |
| 4WRZ10E85-70/6EG24N9EK4/D3M |
| 4WRZ10E85-70/6EG24N9EK4/M |
| 4WRZ10E85-70/6EG24N9K4/D3M |
| 4WRZ10E3-50-70/6EG24N9K4/M |
| 4WRZ10E50-70/6EG24N9TK4/D3M |
| 4WRZ10E50-70/6EG24N9ETK4/D3M |
| 4WRZ10E50-70/6EG24N9ETK4/M |
| 4WRZ10E50-70/6EG24N9EK4/D3M |
| 4WRZ10E50-70/6EG24N9EK4/M |
| 4WRZ10E50-70/6EG24N9K4/D3M |
| 4WRZ10E50-70/6EG24N9K4/M |
| 4WRZ10E25-70/6EG24N9EK4/M |
| 4WRZ10E25-70/6EG24N9K4/D3M |
| h4WRZ10E25-70/6EG24N9K4/M |
| 4WRZ10W6A85-7X/6EG24N9K4/D3M |
| 4WRZ10W6A50-7X/6EG24N9K4/M |
| 4WRZ10W6A25-7X/6EG24N9K4/M |
| 4WRZ10EA50-7X/6EG24N9K4/M |
| 4WRZ10W9-85-7X/6EG24N9K4/D3M |
| 4WRZ10EA25-7X/6EG24N9K4/M |
| 4WRZ10W9-85-7X/6EG24N9EK4/M |
| 4WRZ10W9-85-7X/6EG24N9K4/M |
| 4WRZ10W9-50-7X/6EG24N9EK4/M |
| 4WRZ10W9-50-7X/6EG24N9K4/D3M |
| 4WRZ10W9-50-7X/6EG24N9K4/M |
| 4WRZ10W9-25-7X/6EG24N9EK4/M |
| 4WRZ10W9-25-7X/6EG24N9K4/D3M |
| 4WRZ10W9-25-7X/6EG24N9K4/M |
| 4WRZ10W8-85-7X/6EG24N9ETK4/M |
| 4WRZ10W8-85-7X/6EG24N9EK4/D3M |
| 4WRZ10W8-85-7X/6EG24N9EK4/M |
| 4WRZ10W8-85-7X/6EG24N9K4/D3M |
| 4WRZ10E50-70/6EG24N9TK4/M |
| 4WRZ10W6-25-7X/6EG24N9EK4/D3M |
| 4WRZ10W6-85-7X/6EG24N9K4/D3M |
| 4WRZ10W8-50-7X/6EG24N9EK4/M |
| 4WRZ10W8-50-7X/6EG24N9K4/D3M |
| 4WRZ10W8-50-7X/6EG24N9K4/M |
| 4WRZ10W8-25-7X/6EG24N9EK4/M |
| 4WRZ10W8-25-7X/6EG24N9K4/D3M |
| 4WRZ10W8-25-7X/6EG24N9K4/M |
| 4WRZ10W6-85-7X/6EG24N9TK4/D3M |
| 4WRZ10W6-85-7X/6EG24N9TK4/M |
| 4WRZ10W6-85-7X/6EG24N9ETK4/D3M |
| 4WRZ10W6-85-7X/6EG24N9ETK4/M |
| 4WRZ10W6-85-7X/6EG24N9EK4/D3M |
| 4WRZ10W6-85-7X/6EG24N9EK4/M |
| 4WRZ10W6-85-7X/6EG24N9K4/M |
| 4WRZ10W6-25-7X/6EG24N9EK4/M |
| 4WRZ10W6-50-7X/6EG24N9TK4/D3M |
| 4WRZ10W6-50-7X/6EG24N9TK4/M |
| 4WRZ10W6-50-7X/6EG24N9ETK4/D3M |
| 4WRZ10W6-50-7X/6EG24N9ETK4/M |
| 4WRZ10W6-50-7X/6EG24N9EK4/D3M |
FAQ:
1. Q: Does the 4WRZ10 require a bypass valve for startup?
A: A bypass valve is not mandatory but recommended to flush the system before commissioning, removing contaminants that may damage the valve.
2. Q: How to verify the electrical wiring of the 4WRZ10?
A: Check for correct polarity (solenoid +/-, feedback signals), continuity, and insulation resistance (> 1 MΩ) using a multimeter; refer to the wiring diagram in the manual.
3. Q: What is the maximum allowable backpressure at the T port?
A: The maximum backpressure at the tank port (T) is 10 bar (145 psi); excess backpressure can affect flow regulation and valve performance.
Operation & Control
4. Q: How does the proportional control work in the 4WRZ10?
A: The input electrical signal (4-20 mA/0-10 V) controls the proportional solenoid, which shifts the spool proportionally to adjust the flow rate through ports A/B; position feedback maintains accuracy.
5. Q: Can the 4WRZ10 be operated manually in case of electrical failure?
A: Yes, most models feature a manual override (mechanical lever or hex key) to shift the spool manually for emergency operation.
|
|
4WRZ10E3-85-7X/6EG24N9ETK4/D3M 4WRZ10E3-85-7X/6EG24N9ETK4/M 4WRZ10E3-85-7X/6EG24N9EK4/D3M Original proportional directional valve, German Rexroth Images |