Sign In | Join Free | My benadorassociates.com
China Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. logo
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Verified Supplier

1 Years

Home > Gear Pump >

Rexroth High Pressure Hydraulic Gear Pump for Steel Mill and Industrial Metallurgy Applications with Quantitative Flow

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Rexroth High Pressure Hydraulic Gear Pump for Steel Mill and Industrial Metallurgy Applications with Quantitative Flow

  • 1
  • 2

Brand Name : Rexroth

Model Number : PGH4-2X/063RE07VE4 PGH4-2X/063RR07VU2 PGH4-2X/063LE07VU2 PGH4-2X/063LR07VU2 PGH4-2X/080RE07VU2

Certification : ISO

Place of Origin : German

MOQ : 1

Price : 2

Payment Terms : MoneyGram,Western Union,T/T,D/P,D/A,L/C

Supply Ability : 100

Delivery Time : 2 weeks

Packaging Details : wooden box

whatsapp : +85267220981

Email : Yli97584@gmail.com

Shaft Diameter : 25 mm

Origin : Germany

Theory : Rotary Pump

Seal Type : Lip seal

Warranty : Free Warranty

Pressure : High Pressure

Shaft Type : Keyed

Power : Electric

Rotation : 0.2-cp can be transported in reverse

Contact Now

PGH4-2X/063RE07VE4
PGH4-2X/063RR07VU2
PGH4-2X/063LE07VU2
PGH4-2X/063LR07VU2
PGH4-2X/080RE07VU2 Steel mill industrial metallurgy German Rexroth hydraulic pump quantitative high-pressure gear pump

whatsapp +85267220981 email yli97584@gmail.com
Brand Name Rexroth Place of Origin
Germany
Warranty 12 Months Video outgoing-inspection Provided
Machinery Test Report Provided Application Machinery Repair Shops
Material Iron Condition Oringal
Type PGH4-2X/063RE07VE4
PGH4-2X/063RR07VU2
PGH4-2X/063LE07VU2
PGH4-2X/063LR07VU2
PGH4-2X/080RE07VU2
Quality 100% Tested Great Performance
Certification ISO Feature Long Life Low Noise
Function Filter Diesel Oil Power Hydraulic Power
Payment Term T/T 100%

Rexroth High Pressure Hydraulic Gear Pump for Steel Mill and Industrial Metallurgy Applications with Quantitative Flow

PGH5-2X/160RE07VU2 PGH4-2X/050RE11VE4 PGH3-1X/016RF07MK0
PGH5-2X/125RR11VU2 PGH4-2X/040RE11VU2 PGH3-1X/016RE07ME4
PGH5-2X/125RE11VU2 PGH4-2X/032RR11VU2 PGH3-1X/016LE07MU2
PGH5-2X/125RE11VE4 PGH4-2X/032RE11VU2 PGH3-1X/010RE07MU2
PGH5-2X/100RE11VE4 PGH4-2X/032RE11VE4 PGH2-X/008LR07VU2
PGH5-2X/100LF11VK0 PGH4-2X/025RE11VU2 PGH2-X/008LE07VU2
PGH5-2X/080RR18VU2 PGH4-2X/025RE11VU2 PGH2-X/006RE07VU2
PGH5-2X/080RE11VE4 PGH4-2X/025RE11VE4 PGH2-X/005RR07VU2
PGH5-2X/063RR11VU2 PGH4-2X/020RE11WU2 PGH2-2X/008RR07WU2
PGH5-2X/063RE11VU2 PGH4-2X/020RE11VU2 PGH2-2X/008RE07WU2
PGH5-2X/063RE11VE4 PGH4-2X/020LR18VU2 PGH2-2X/008RE07VU2
PGH5-21/160RE07VU2 PGH4-21/050RE11VE4 PGH2-2X/008LR07VU2
PGH5-21/125RE11VE4 PGH4-21/040RE11VU2 PGH2-2X/008LE07VU2
PGH5-21/080RE11VU2 PGH4-21/032RE11VE4 PGH2-2X/006RE07VU2
PGH4-3X/050RE11VU2 PGH4-21/025RE11VU2 PGH2-2X/005RR07VU2
PGH4-3X/020RR11VU2 PGH3-2X/016RE07VU2 PGH2-2X/005RE07VU2
PGH4-2X/100RE07VU2 PGH3-2X/013RR07VU2 PGH2-1X/006RE07MU2
PGH4-2X/080RF07VK0 PGH3-2X/013RE07VU2 PGH2-1X/006RE07ME4
PGH4-2X/080LF47VK0 PGH3-2X/011RE07VU2 PGH2-1X/005RE07MU2
PGH4-2X/063RE07VE4 PGH3-2X/011LR07VU2 PGH2-1X/005LE07MU2
PGH4-2X/050RE11VU2 PGH3-2X/011LE07VU2

FAQ:

What precautions should be taken during the installation of PGH Series Gear Pumps?

• Ensure the pump’s rotational direction matches the system’s requirements (reverse rotation can cause internal component damage).

• Keep the suction line length within 1 meter and avoid sharp bends to prevent insufficient oil suction.

• Tighten the flange bolts to the torque specified in the manual (typically 18-22 N·m for standard models) to avoid oil leakage or housing deformation.

3. How to resolve abnormal noise from a PGH Series Gear Pump during operation?

First, check if the hydraulic oil level is too low (topping up to the standard level if needed); second, inspect for air bubbles in the oil circuit (bleeding the system to remove air); finally, check if the bearing is worn (replacing the bearing if there is excessive radial play).

4. How often should maintenance be performed on PGH Rexroth Gear Pumps?

For general industrial applications, routine inspection (checking oil level, temperature, and leakage) should be conducted monthly; oil change and filter replacement are recommended every 6 months or after 2000 hours of operation; a comprehensive disassembly and inspection of the pump should be carried out every 2-3 years.

5. Can PGH Rexroth Gear Pumps be used in high-temperature environments for a long time?

No. The maximum allowable long-term operating temperature of PGH Rexroth Gear Pumps is 80°C. Prolonged use in environments exceeding this temperature will accelerate the aging of internal seals and bearings, significantly reducing the pump's service life and even causing sudden failures.


Product Tags:

Steel Mill Hydraulic Gear Pump

      

Industrial Metallurgy Gear Pump

      

Quantitative Rexroth Gear Pump

      
Quality Rexroth High Pressure Hydraulic Gear Pump for Steel Mill and Industrial Metallurgy Applications with Quantitative Flow for sale

Rexroth High Pressure Hydraulic Gear Pump for Steel Mill and Industrial Metallurgy Applications with Quantitative Flow Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)